Instrument Catalogue

Explore our instrumentation capabilities and key specifications. For detailed technical requirements or to discuss your testing and analysis needs, please contact our team.

Separation & Identification

Purity assessment, impurity profiling, residual solvent analysis, volatile compound identification, and formulation characterisation.

High-Performance Liquid Chromatography (HPLC)

Thermo Fisher Vanquish Core

Separates and quantifies components of a mixture using a liquid mobile phase — the workhorse technique for purity and impurity analysis.

KEY SPECS

Max. pressure: 700 bar · 4-channel quaternary gradient · Column temp: 5°C–85°C

Ultra-High Performance Liquid Chromatography (UHPLC)

UltiMate Dionex 3000

A faster, higher-resolution advancement over HPLCusing sub-2-micron particle columns for sharper separations in less time.

KEY SPECS

Sub-2-microncolumn capability · DAD / UV & RI detection · High-pressure gradient system

Liquid Chromatography–Mass Spectrometry (LC-MS/MS)

Waters ACQUITY UPLC H-Class PLUS + Xevo TQ-S cronos

Couples UPLC separation with tandem quadrupole massspectrometry for high-sensitivity, targeted quantitation of trace-level compounds.

KEY SPECS

Max. pressure: 15,000 psi · MRM sensitivity: >75,000:1 S/N (ESI+) · Quaternary solvent blending

Gas Chromatography (GC-FID)

Thermo Fisher TRACE 1600 Series

Separation and quantification of volatile and semi-volatile organic compounds using flame ionisation detection.

KEY SPECS

Temprange: Ambient +3°C–450°C · Heat-up: 125°C/min max · Split/splitless inlet

Gas Chromatography Mass Spectrometry (GC-MS/MS)

Thermo Fisher TRACE 1610 Series (GC); TSQ 9610 (MS)

Combines chromatographic separation with mass-spectral identification for trace-level detection of organic compounds.

KEY SPECS

Triplequadrupole detection · High sensitivity, low detection limits · Combustion/pyrolysis-ready sample prep

Flash Chromatography

puriFlash XS 530

Performs automated flash chromatography for purification and isolation of organic compounds using normal-phase or reverse-phase columns.

KEY SPECS

Flow rate: 300mL/min · Pressure: 30 bar · Pump: Quaternary gradient · Detector: UV-Vis DAD (200–400 nm; optional 200–800 nm) · Fraction collector: 112 tubes · Column compatibility: Normal-phase & Reverse-phase

Microplate Reader

LTEK, INNO Microplate Reader (Absorbance)

Performs automated flash chromatography for purification and isolation of organic compounds using normal-phase or reverse-phase columns.

KEY SPECS

Detection:UV-Vis Absorbance · Wavelength: 200–999 nm · Optics: Monochromator · Light source: Xenon flash lamp · Plate format: 6–384 well · Dynamic range: 0–4.0 OD · Connectivity: USB, RS-232

Nano Drop

Thermo Scientific, NanoDrop™ OneC Microvolume UV-Vis Spectrophotometer

Performs automated flash chromatography for purification and isolation of organic compounds using normal-phase or reverse-phase columns.

KEY SPECS

Wavelength: 190–850nm · Sample volume: 1–2µL · Pathlength: Auto-ranging(0.03&0.67mm) · Detection range: 2–27,500 ng/µL (dsDNA) · Measurement time: <5 s · Detection modes: Microvolume UV-Vis & Cuvette

Elemental and Compositional Analysis

Heavy metals, trace elements, alloy, feed and water composition panels.

Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES)

Thermo Fisher iCAP PRO

Uses high-temperature argon plasma to excite sample atoms, enabling simultaneous multi-element analysis from major constituents down to trace (ppb) levels.

KEY SPECS

Wavelength range: 167–852 nm · Simultaneous echelle spectrometer · RF source: 27 MHz, 1150 W

CHNS/O Elemental Analyser

Thermo Fisher Flash Smart

Precise, rapid determination of carbon, hydrogen, nitrogen, sulphur and oxygen content across solids, liquids and powders.

KEY SPECS

Analysis range:ppm to 100% · Combustion or pyrolysis modes · Dual-furnace automated system

Spectroscopy and Structural Analysis

Phaseidentification, polymorphism, microstructure, and material/coating identity.

Powder X-Ray Diffraction (XRD)

Bruker D8 Advance

Identifies crystalline materials, determines purity, and characterises structural and phase properties of a sample.

KEY SPECS

Cusource, sealed tube · Bragg-Brentano geometry · LYNXEYE 1D detector

Fourier Transform Infrared Spectroscopy (FTIR-ATR)

Thermo Fisher Nicolet Summit X

Rapid, non-destructive molecular and functional-group characterisation with minimal sample preparation.

KEY SPECS

ATRsampling mode · DTGS detector · Direct solid/liquid/film measurement

UV-Visible Spectroscopy (UV-Vis)

Thermo Fisher Evolution One

Detects the presence and concentration of substances in solution, along with reaction kinetics, across a wide wavelength range.

KEY SPECS

Wavelengthrange: 190–1100 nm · Double-beam Czerny-Turner optics · Xenon light source

Atomic Absorption Spectroscopy (AAS)

Thermo Fisher iCE 3000

Rapid, highly sensitive detection of trace metals in liquids using flame or graphite-furnace atomisation.

KEY SPECS

Dual-beam optics · Flame and furnace modes · 6-lamp auto-aligning carousel

Polarising Light Microscope

Leica DM750M

High-magnification optical examination of crystalline and fibrous structures under polarised, brightfield and oblique light.

KEY SPECS

Magnification up to 500X · 4-segment LED illumination · Integrated imaging stage

Materials Characterisation

Polymer, rubber, leather and packaging compounding, mechanical and barrier testing.

Universal Testing Machine (UTM)

Instron BI-7003, 25 kN

Measures the tear strength of paper, sheet materials and leather for quality control and performance assessment.

KEY SPECS

Key specs: Capacity: 25 kN · 2-column frame · Load cell accuracy: 0.3%

Elmendorf Tear Tester

Hexaplast HP-ETT1

High-magnification optical examination of crystalline and fibrous structures under polarised, brightfield and oblique light.

KEY SPECS

Capacity: up to 6400 g · Tearing distance: 43±1 mm · 0–100% scale reading

Bally Water Penetration Tester

Gester GT-KC06A

Assesses the flex resistance and durability of leather and coated fabrics under repeated flexing cycles.

KEY SPECS

4test positions · Standard specimen size · Controlled ambient conditions

Water Vapour Permeability Tester

Gester GT-KC211

Assesses the water vapour permeability of leather, rubber-like materials, and packaging films.

KEY SPECS

6testing bottles · Controlled RH & temperature · Touch-screen control

Two-Roll Mill

Hexaplast HP-TRM-1

Used for mixing and compounding rubber and elastomeric materials, ensuring thorough dispersion of fillers, additives and colorants.

KEY SPECS

Rubber/elastomer compounding · Adjustable roll gap · Batch mixing capability

Laboratory Extruder

Hexaplast HP-LE-01

A small-scale extrusion line used to process and evaluate polymer and compound formulations prior to scale-up.

KEY SPECS

Output: 3–5kg/hr · Screw L/D ratio: 25:1 · 0–75 RPM screw speed

Compression Moulding Press

SANTOSH SHP-37

A hydraulic press used to shape thermosetting plastics and rubber compounds by applying heat and pressure.

KEY SPECS

Hydraulicheat-and-pressure moulding · Suited to thermosets & rubber · Configurable moulding cycles